On Site Pipette Calibration

Pipettes

Microscopes

Microscopes

Medical Equipment Supplier in Ohio

Services include preventative maintenance and calibration. 

  • Disassemble the pipette
  • Clean the shaft, piston and all internal parts with acetone and hi-gloss metal polish
  • Replace Teflon seal and o-ring
  • Lubricate any necessary parts
  • Reassemble pipette and make necessary adjustments
  • Clean exterior, clean ejector
  • Calibrate pipette to manufacturer’s specs
  • Apply calibration sticker with calibration date and due date
  • 6 month warranty on calibration and 1 year warranty on part

Microscopes

Microscopes

Microscopes

Medical Equipment Services in Ohio

Depending on their use, microscopes should receive routine preventative maintenance service once, twice or even four times a year.

  • Disassemble, clean, degrease, lubricate and reset moving parts to factory specifications
  • Remove, clean, check and par-focal all optics
  • Clean interior prisms and inspect for proper alignment
  • Remove, clean and align sub-stage condenser (if required.)
  • Test and set electrical system to specifications
  • Performance check focusing mechanisms
  • Reassemble and individually test each microscope 

Balances/Scales

Balances/Scales

Balances/Scales

On-site cleaning and calibration

  • Cornerload, repeatability and linearity tests
  • "As Found" and "As Left" Data
  • Cleaning of draft shield, housing, weighing pan, weighing chamber and door track
  • Adjustment of the scales using a weight matching procedure to ensure accurate and consistent readings
  • Re-leveling of the Balance/Scale

Centrifuges

Balances/Scales

Balances/Scales

 

  • Calibrated by checking the rotation speed using a NIST-Traceable photo-tachometer.
  • Units equipped with timing devices are also tested by direct comparison with NIST-Traceable stopwatch.
  • Temperature verification of refrigerated centrifuges are available on most units.
  • On all units, we perform a safety inspection of the instrument prior to beginning work and general cleaning afterward.
  • A calibration label is affixed to the centrifuge and a calibration report is provided.

Copyright © 2020 On Target Calibration - All Rights Reserved. Phone:  (856) 545-3439 

Powered by GoDaddy Website Builder

  • On-Site Services
  • Mail-In Services
  • Contact Us
  • On-Site Service Locations
  • About Us
  • FAQ's

Cookie Policy

This website uses cookies. By continuing to use this site, you accept our use of cookies.

Accept & Close